Vertix Diagnostics performs field water penetration testing in New York City: storefronts, curtain walls, windows, doors, skylights, facades and brick and masonry walls, tested to ASTM E1105 and AAMA 501.2, 502, 503 and 511. We test new construction for quality assurance, and we run forensic water intrusion tests on buildings that already leak to find the exact point of failure. Across the five boroughs, the work splits between quality assurance testing on new construction, window replacement programs in existing masonry buildings, and forensic testing where a facade, storefront or window is already leaking.
We test and report; we do not install, seal or repair. The report goes to your general contractor, glazing subcontractor or envelope consultant to act on.
Certified Infrared ThermographerInfraspection Institute · FLIR E96 & T865
ASTM International MemberASTM C1153-23 · ASTM E3216-26
AAMA 501.2: Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems
Water testing in New York City
What we test most in New York City.
Curtain wall, window wall and punched windows on towers
Quality assurance testing during installation, usually from a swing stage or mast climber: AAMA 501.2 nozzle testing on curtain wall joints and ASTM E1105 chamber testing on operable windows and balcony doors, early enough that a defect is corrected before it repeats on every floor.
Window replacement programs in masonry buildings
When a building replaces hundreds of windows, testing the first installations to ASTM E1105 confirms the installer's flashing and perimeter seal before the rest go in. Where water is already coming in, forensic testing separates the window from the lintel, pointing or parapet above it.
Brownstone and brick row-house facades
Rear window and door replacements, parlor-floor entries and old brick are the usual suspects. Brick wall water leak testing to ASTM C1601 and component-by-component spray testing separate porous masonry and failed pointing from a leaking window or door.
Storefronts, office fronts and ribbon windows
Commercial and industrial buildings rely on aluminum storefront entrances, ribbon windows and metal panel joints. Storefront water testing to AAMA 501.2 checks the glazing seals, mullion joints and sill details where these systems usually fail.
Testing services
Five tests, written standards.
Professional AAMA 501.2 testing of storefronts, curtain walls and sloped glazing, ASTM E1105 chamber testing of windows and doors, and ASTM C1601 testing of brick and masonry walls.
Every test follows a published ASTM or AAMA method, at the pressure, spray rate and duration your specification sets. Results are documented opening by opening, with photographs, so they stand up on the project record.
For new construction, testing a sample of the first installations, commonly around 20% of the fenestrations, catches installation defects while the trade is still on site. For existing leaks, forensic testing works upward one component at a time until the source is isolated, and the same location is retested after the repair.
Our spray rack and test equipment is portable, so we come to the building. Vertix Diagnostics is based on Long Island and serves New York City, Long Island, northern and central New Jersey, and southwestern and central Connecticut.
Vertix Diagnostics
1208 W Broadway Hewlett, NY 11557 (516) 234-5012
Sun–Fri 8 AM–8 PM · Sat closed
Do you offer ASTM and AAMA water testing in New York City?
Yes. Vertix Diagnostics performs field water penetration testing throughout New York City: storefront water testing, forensic water intrusion testing, masonry wall drainage testing, facade testing and brick wall water leak testing, following ASTM E1105, AAMA 501.2: Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems, AAMA 502, 503 and 511, and ASTM C1601. Call (516) 234-5012 or request testing on this page.
Which water test does my project in New York City need?
The project specification usually names it. ASTM E1105 is the common method for windows and doors, using a spray rack with an air pressure difference. AAMA 501.2 uses a calibrated nozzle along the joints of storefronts, curtain walls and sloped glazing. For a building that already leaks, forensic testing under AAMA 511 isolates the source one component at a time. We help you match the method to the specification before the test date.
Do you test new construction and existing buildings in New York City?
Both. On new construction we perform quality assurance testing, commonly on around 20% of the windows and doors, so installation defects are corrected before turnover. On existing buildings in New York City we perform forensic cause-and-origin testing to find where water is getting in, then retest after the repair to confirm it worked.
Do you repair what fails the test?
No. We test and report; we do not install, seal or repair. Because we have no stake in the repair, general contractors, architects, owners and insurance carriers can rely on the result. The report goes to whichever contractor you choose.
A plumber who finds your leak also sells you the repair. A roofer who inspects your roof also quotes the replacement. That isn't dishonesty — it's structure, and it quietly shapes every finding. We are an independent diagnostic company: we do not perform repairs, we do not sell materials, and we take no referral fee from any contractor. The report is the entire product, so there is nothing for us to gain by finding more than is there.
No repair revenue
We can't profit from the work we recommend, because we don't do the work. If your roof is 8% wet, the report says 8% — not "replace the field."
No referral fees
We accept nothing from contractors for sending work their way. Take our findings to your own plumber, roofer, or electrician, or put them out to bid.
Findings that carry weight
Boards, managing agents, and insurance carriers treat an independent finding differently than an estimate from the company that wants the job.
We'll tell you it's nothing
Sometimes the answer is condensation, or a warm duct, or a neighbor's roof. We're paid the same either way, so we say so.